Radon Concentrations Measurement for Drinking Water in Kufa City /Iraq Using Active Detecting Method
Abstract
In this research , radon concentrations in drink water samples were measured in Kufa city – Iraq by using a technique called Durridge RAD7-H2O with closed loop. The studied sites on the map of Kufa city were determined by using GIS program.
It was found that , the range of radon concentrations for the studied area between (3.9±0.0432- 226±8.876) Bq/m3, while the range of mean annual effective dose between (0.54834- 31.7756) µS.y-1.
When the results were compared of radon concentrations with the internationally recommended reference levels (World health Organization limit 500 Bq/m3) and the mean effective annual dose for radon in drink water normal limits of world (1 mSv/y), there were no indications of existence of radon problems in the water sources in this survey. therefore the drinking water in Kufa city is safe as far as radon concentration is concerned.
Keyword : Radon in drinking water, Kufa city/Iraq, RAD-7 detector
To list your conference here. Please contact the administrator of this platform.
Paper submission email: APTA@iiste.org
ISSN (Paper)2224-719X ISSN (Online)2225-0638
Please add our address "contact@iiste.org" into your email contact list.
This journal follows ISO 9001 management standard and licensed under a Creative Commons Attribution 3.0 License.
Copyright © www.iiste.org